I-EMR EDS Instrument Polypectomy Ugibe Olubandayo Lokusetshenziswa Okukodwa

I-EMR EDS Instrument Polypectomy Ugibe Olubandayo Lokusetshenziswa Okukodwa

Incazelo emfushane:

Izici

● Yenzelwe ama-polyps <10 mm

● Intambo ekhethekile yokusika

● Idizayini yogibe ethuthukisiwe

● Ukusika okuqondile, okufanayo

● Izinga eliphezulu lokulawula

● Ukubamba kwe-ergonomic


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Isicelo

I-Cold Snare iyithuluzi elifanele ngaphezu kwakho konke ukukhishwa okubandayo kwama-polyps< 10 mm.Le ntambo yokusika ezacile, ephothiwe yathuthukiswa ngokukhethekile ukuze isuswe emakhazeni futhi yenza ukusika okunembe kakhulu, okuhlanzekile kuhlanganiswe nomklamo wogibe olungiselelwe ukusika ama-polyp amancane.I-polyp ekhishiwe ayinazo izici ezishisayo futhi iqinisekisa ukuthi ukuhlolwa kwe-histological kuzohlinzeka ngolwazi olubalulekile.

Ukucaciswa

Imodeli Ububanzi beluphu D-20% (mm) Ubude Bokusebenza L ± 10% (mm) I-Sheath ODD ± 0.1 (mm) Izici
ZRH-RA-18-120-15-R 15 1200 Φ1.8 I-Oval Snare Ukuzungezisa
ZRH-RA-18-160-15-R 15 1600 Φ1.8
ZRH-RA-24-180-15-R 15 1800 Φ2.4
ZRH-RA-24-230-15-R 15 2300 Φ2.4
ZRH-RB-18-120-15-R 15 1200 Φ1.8 I-Hexagonal Snare Ukuzungezisa
ZRH-RB-18-160-15-R 15 1600 Φ1.8
ZRH-RB-24-180-15-R 15 1800 Φ1.8
ZRH-RB-24-230-15-R 15 2300 Φ2.4
ZRH-RC-18-120-15-R 15 1200 Φ1.8 I-Crescent Snare Ukuzungezisa
ZRH-RC-18-160-15-R 15 1600 Φ1.8
ZRH-RC-24-180-15-R 15 1800 Φ2.4
ZRH-RC-24-230-15-R 15 2300 Φ2.4

Incazelo Yemikhiqizo

certificate

360°I-Rotatable Snare Degign
Nikeza ngokuzungezisa okungu-360 ukuze usize ukufinyelela kuma-polyp anzima.

Intambo Ekwakhiweni Okulukiwe
kwenza ama-polys angabi lula ukushelela

I-Soomth Open and Close Mechanism
ukuze kube lula ukuyisebenzisa

I-Rigid Medical Stainless-Stainless
Nikeza izici eziqondile nezisheshayo zokusika.

certificate
certificate

Isigodlo esibushelelezi
Vimbela umonakalo esiteshini sakho se-endoscopic

Uxhumano Lwamandla Olujwayelekile
Ihambisana nawo wonke amadivaysi aphezulu anemvamisa ephezulu emakethe

Ukusetshenziswa Kwezokwelapha

I-Polyp eqondiwe Ukukhipha Ithuluzi
Usayizi we-Polyp <4mm Ama-forceps(usayizi wenkomishi 2-3mm)
I-Polyp ngosayizi we-4-5mm Ama-Forceps(usayizi wenkomishi 2-3mm) I-Jumbo forceps(usayizi wenkomishi>3mm)
Usayizi we-Polyp <5mm Ama-forceps ashisayo
I-Polyp ngosayizi we-4-5mm I-Mini-Oval Snare(10-15mm)
I-Polyp ngosayizi we-5-10mm I-Mini-Oval Snare(kuyakhethwa)
I-Polyp> 10mm ngosayizi I-Oval, Izingibe Ezine-Hexagonal
certificate

Izinyathelo zokuphepha zokusishulwa kogibe olubandayo lwe-polyp

1. Ama-polyps amakhulu anomkhawulo.
2. Ifanele i-EMR kanye ne-ESD endoscopy, i-EMR evuthiwe nephelele noma ubuchwepheshe bokususa i-ESD bungakhethwa.
3. I-polyp ye-pedicle nayo ingabanjwa ngokuqondile ukusika kagesi, hhayi ukusika okuhle nokukhethekile okubandayo, futhi ingaphakathi le-pedicle lishiywe, futhi isiqeshana singabamba impande.
4. Ugibe oluvamile lungasetshenziswa futhi, futhi ugibe olukhethekile oluncane lwe-polyp lufaneleka kakhulu ukusika okubandayo.
5. Ukukhishwa okubandayo ezincwadini akuvumelekile, futhi ukukhishwa kukagesi akubanjwanga ngokuqondile, futhi ekugcineni kushintshelwe ku-EMR.
6. Qaphela ukusika okuphelele.
Izehlakalo nokufa komdlavuza wamathumbu njengomdlavuza we-colorectal kusalokhu kuphezulu.Amazinga okugula nokufa aphakathi komdlavuza ophezulu, futhi ukuhlolwa okufika ngesikhathi kufanele kwenziwe uma kunesidingo.


  • Okwedlule:
  • Olandelayo: